Axial Plunger High Pressure Pump
DHP 1.7 Axial Piston Pumps Complete Guide to Parameters (3000rpm/1.7m³/h) Maintenance & Warranty
DHP 1.7 Axial Piston Pumps: Complete Guide to Parameters (3000rpm/1.7m³/h), Maintenance & Warranty for Industrial Reverse Osmosis High Pressure Pump High-pressure pumps for onshore, offshore and marine reverse osmosis applications; reliable replacement for Danfoss APP and APP W HC RO high-pressure pumps.
In medium-low flow and high-pressure fluid transfer scenarios, such as island seawater desalination and industrial wastewater treatment, DHP 1.7 Axial Piston Pumps (high-pressure piston pumps) have always been popular due to their accurate parameters, strong corrosion resistance, and easy maintenance. Below, we will discuss practical information about this pump, covering parameters, maintenance, and warranty—all core content from the manual.
1. DHP 1.7 Core Parameters: Low and Medium Flow Demand Table
The DHP 1.7's parameters are fully suitable for high-pressure fluid transfer in small and medium-sized projects. Key data are shown in the table below. A "DHP 1.7 Parameter Label Chart - 3.0 Series" is also included below to provide a more intuitive understanding of the relationship between parameters and device structure:
| Parameter Category | Specific Value/Specification | Note (from the manual) |
|---|---|---|
| Geometric Displacement | 9.6 cm³/rev | Specified in the manual as the basic displacement of this series, determining the basis for flow calculation |
| Rated Speed | 3000 rpm | Specified in the manual as the normal operating speed; adjustable range is marked next to the diagram |
| Rated Water Output | 1.7 m³/h | Stable output at 3000 rpm, verified by the flow curve in the manual |
| Outlet Pressure Range | Minimum 20 Bar, Maximum Continuous 80 Bar | The manual emphasizes that overpressure triggers the safety valve; the safety valve position is marked in the diagram |
| Inlet Pressure Range | 1-5 Bar | The manual warns that cavitation is likely to occur when pressure is below 1 Bar, requiring monitoring with a pressure gauge |
| Equipment Weight | 7.8 kg | Weight is marked next to the dimension diagram in the manual, suitable for installation in narrow spaces |
| Inlet/Outlet Interface | G3/4〞 (depth 18 mm) | Interface specifications are clearly stated in the interface detail diagram of the manual, enabling direct connection to industrial pipelines |
| Operating Noise | ≤77 dB(A) | Tested and marked in the manual in accordance with EN ISO 3744-2010 standard |
| Core Material | 2205 Duplex Stainless Steel (SAF 2205/EN 1.4462/UNS 31803) | Its corrosion resistance is highlighted in the material description section of the manual |
| Designed Service Life | Over 8000 hours | This parameter is linked in the warranty terms of the manual, serving as the basis for maintenance cycles |
| Special Design | Integrated Flush Check Valve, No Lubricating Oil Tank | The check valve position is marked in the manual's structural diagram, explaining the advantages of the oil-tank-free design |
2. DHP 1.7 Flow Characteristics: Flow Curve Visualization
The figure below shows the flow curve for the DHP 1.7 at 80 bar pressure. It clearly shows that within the speed range of 700-3450 rpm, the flow rate varies linearly with speed, accurately reaching 1.7 m³/h at 3000 rpm, consistent with the datasheet. This also provides a basis for speed adjustment under different operating conditions.

3. DHP 1.7 Installation and Dimensions: Dimensional Drawings + Installation Guide
Below are detailed installation dimensions and interface specifications for the 3.0 series (including DHP 1.7). Installation information is as follows:

Complete equipment with independent fan motor (frequency conversion motor) Unit: mm
Plunger pump | A | B | H | K | P | AD | HD | C | D | L | G | IEC Motor |
DHP0.6 ~1.0 | 125 | 100 | 80 | 10 | 200 | 145 | 225 | 133 | 100 | 325 | 558 | 1.1kW-2P |
140 | 100 | 90 | 10 | 200 | 165 | 255 | 133 | 100 | 340 | 573 | 1.5kW-2P | |
140 | 125 | 90 | 10 | 200 | 165 | 255 | 133 | 100 | 365 | 598 | 2.2 kW -2P | |
160 | 140 | 100 | 12 | 250 | 175 | 275 | 133 | 120 | 405 | 658 | 3.0 kW -2P |
4. DHP 1.7 Power Matching Accurate Power Meter
The power data of the DHP 1.7 is as follows. We have also attached a "Quick Power Relationship Chart" to facilitate quick motor matching:
| Working Condition | Power | Note from the Manual |
|---|---|---|
| 3000rpm, 60Bar Pressure | 4kW | Basic working condition value in the manual's power table |
| 3000rpm, 70Bar Pressure | 5.5kW | Recommended motor power for common working conditions |
| 3000rpm, 80Bar Pressure | 5.5kW | The manual emphasizes this power as the upper limit for continuous operation |
Pump Model | Rated flow | Typical pressure | Rated speed | |||
L/ min | m3 / h | 60 Bar | 70 Bar | 80 Bar | rpm | |
| DHP1.7 | 26 | 1.7 | 4kW | 5.5kW | 5.5kW | 3000 |
5. Maintenance Requirements and Guidelines for DHP 1.7
Maintenance can be divided into three parts: routine maintenance, shutdown maintenance, and troubleshooting:
1. Daily Maintenance: 3 Inspections as Required by the Manual
2.Shutdown Maintenance Period Requirements
3. Troubleshooting: Troubleshooting Guide
6. Warranty Service of DHP 1.7: Clear Guarantee from Manual Terms
The warranty policy is as follows:
7. Customer Feedback and Manufacturer Strength
To view the complete parameter diagrams, installation details, and warranty terms in the manual, please refer to the manual, or visit the manufacturer's official website (https://www.fgwater.com) and call the customer service hotline [+86-13646187144(Whats App same number)] to obtain the electronic manual.
PDF manual download address:DHP type plunger pump selection manual
Send Your Water Treatment Requirement
Tell us the feedwater, required capacity, target water quality and project conditions. Your inquiry email will automatically include the page you are viewing so our team can understand the exact product, technology or reference that led to your request.
- Feedwater source / available analysis
- Design flow or required production capacity
- Target product-water quality or process duty
- Project country, operating conditions and delivery target