FENIGAL-FG Water Technologies
Tel: +86-13646187144 [email protected] Industrial Water Systems · Membranes · EDI · Desalination
FENIGAL-FG Water Technologies Wuxi Fenigal · Industrial Water Division
Translate this website

Google Translate is loaded only when you open this panel, reducing unnecessary requests and layout work during the first page load.

Loading language options…
Request Quote

Dupont Dow's Ultrafiltration Membrane Modules

Professional Product Detail

Dupont SFP-2860 PVDF Ultrafiltration Membrane Module with 0.03μm Pore Size for RO Pretreatment

产品描述(Product Description)The SFP-2860 Ultrafiltration (UF) Membrane Module is a high-performance pressurized membrane designed for reliable removal of suspended solids, bacteria, viruses, and colloidal particles.Constructed with hydrophilic PVDF hollow fiber membranes, the module offers excellen

Category: Dupont Dow's Ultrafiltration Membrane Modules
Dupont SFP-2860 PVDF Ultrafiltration Membrane Module with 0.03μm Pore Size for RO Pretreatment

产品描述(Product Description)

The SFP-2860 Ultrafiltration (UF) Membrane Module is a high-performance pressurized membrane designed for reliable removal of suspended solids, bacteria, viruses, and colloidal particles.

Constructed with hydrophilic PVDF hollow fiber membranes, the module offers excellent mechanical strength, superior chemical resistance, and long service life. The outside-in flow configuration allows operation with higher feed water solids, reducing pretreatment requirements and minimizing operational costs.

With a compact structure and optimized membrane area, the SFP-2860 is particularly suitable for systems with height limitations while maintaining stable filtration performance.

This module is widely used in industrial water treatment, municipal water purification, and pretreatment for reverse osmosis (RO) systems.

核心卖点(Key Features)

  • 0.03 μm nominal pore size for effective removal of bacteria and viruses

  • High-strength PVDF hollow fiber membrane

  • Hydrophilic membrane for easy cleaning and stable flux

  • Outside-in filtration design, tolerant to high turbidity feed water

  • Reduced backwash consumption

  • Compact design suitable for skid-mounted systems

  • Long membrane lifespan and stable performance

产品应用(Applications)

  • Surface water treatment

  • Seawater pretreatment

  • Industrial wastewater reuse

  • Municipal water treatment

  • RO pretreatment systems

  • Ultra-pure water (UPW) pretreatment

1776387069173682.jpg

1776387071682261.jpg

Product Specifications


Membrane area


Module volume

Weight

(empty/ water filled)

ModelTypePart #m²ft²LitersGallonsKglbs
SFP-2860Pretreatment28093351549359.348/83106/183
SFD-2860

NSF/ANSI 61

Drinking water

32416851549359.348/83106/183
Properties
Length

DiameterWidth
UnitsLL1L2L3DW1W2
SI (mm)1860150016301820225180342

Operating Parameters


SI unitsUS units
Filtrate Flux @ 25ºC40-120 l/m²/ hr24-70 gfd
Flow range2.0 – 6.1 m³/hr9.2 – 26.7 gpm
Temperature1-40ºC34-104ºF
Max. inlet module pressure (@ 20ºC)6.25 bar93.75 psi
Max. operating TMP2.1 bar30 psi
Max operating air scour flow12 nm³/hr7.1 scfm
Max backwash pressure2.5 bar36 psi
Operating pH2- 11
NaOCl (max.)2,000 mg/L
TSS (max.)100 mg/L
Turbidity (max.)300 ntu
Particle size (max.)300 µ
Flow configurationOutside in, dead end flow
Expected filtrate turbidity≤0.1 NTU
Expected filtrate SDI≤2.5

Important information

Proper start-up of a UF system is indispensable for preparing the membranes for operational service and preventing membrane damage. Adhering to the correct start-up sequence also contributes to ensuring that the operating parameters of the system conform to the design specifications, thereby enabling the attainment of system water quality and productivity targets. Before commencing the system start-up procedures, membrane pretreatment, installation of the membrane modules, instrument calibration, and other system checks should be accomplished. Kindly refer to the product technical manual.

Operation guidelines

Avoid any sudden pressure fluctuations during start-up, shutdown, cleaning or other processes to prevent potential membrane damage. Flush the UF system to eliminate the shipping solution before start-up. Remove the residual air from the system before start-up. Manually initiate the equipment. Aim for a permeate flow of 60% of the design during the initial operations. Depending on the application, the permeate obtained from the initial operations should be disposed of. Please refer to the product technical manual.

Regulatory note

NOTICE: NSF/ANSI 61 certified drinking water modules demand specific conditioning procedures before generating potable water. Please refer to the flushing section of the product technical manual for detailed procedures. Drinking water modules might be subject to additional regulatory constraints in certain countries. Please verify local regulatory guidelines and the application status before usage and sale.

The utilization of this product does not inevitably ensure the elimination of cysts and pathogens from water. Effective reduction of cysts and pathogens depends on the complete system design as well as the operation and maintenance of the system.

Notice: No inference should be made regarding the absence of infringement of any patent owned by Dow or others. As the use conditions and applicable laws may vary from one location to another and may change over time, the Customer is accountable for determining whether the products and the information in this document are suitable for the Customer's use and for ensuring that the Customer's workplace and disposal practices comply with applicable laws and other governmental enactments. The product presented in this literature might not be available for sale and/or available in all geographical areas where Dow is represented. The claims made might not have been approved for use in all countries. Dow assumes no obligation or liability for the information in this document. References to "Dow" or the "Company" signify the Dow legal entity selling the products to the Customer unless otherwise explicitly noted. NO WARRANTIES ARE PROVIDED; ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY DISCLAIMED.

About Us

FG Water Technologies (www.fgwater.com) is now an organic part of Wuxi Fenigal Science and Technology Co. Ltd., which is a high-tech entity integrating water treatment quipment design, manufacturing, trading and shipment served for main industrial sectors.

HAFE-FG Water Technologies has focused on the research of water treatment technology, equipment development and manufacturing, testing and international shipment etc. We work with many leading large-scale or small-medium original equipment manufacturers in China High-tech Development Zones, and engaged ourselves in R&D, manufacturing, and quality testing.

Our main products include a variety of water purification and different treatment equipment, such as seawater reverse osmosis (SWRO) system, brackish water rever osmosis (BWRO), ultrafiltration (UF)system, Electrodeionization/EDI equipment, media pressure filters and ion exchanger softeners. So far, our company has become a major water treatment equipment supplier for food and beverage industry, pharmaceutical industry, chemical industry, electric power industry, urban water supply industry, municipal and industrial wastewater treatment and more industries, as well as being an exporter to more than 20 countries and regions in Asia, Europe, the Americas, Africa, etc.


PRODUCTION SYSTEM

Our production system consist of a list of industry-specialized partnership factories accross China. Some of them singularly cover an area of over 10,000 square meters, including 5,000 square meters of workshop and warehouse and 1,500 square meters of office buildings. All of our technical staff has more than 10 years of experience in the design of water treatment systems, so we are able to provide the perfect solution for all kinds of water purification and sewage treatment applications.

Since the establishment, the Company has always regarded quality as the life of our business. We choose the best components only for the production of various water treatment systems. Our systems are easy to use and maintain, and they stays highly reliable even under toughest conditions.


Project Inquiry · Technical & Commercial

Send Your Water Treatment Requirement

Tell us the feedwater, required capacity, target water quality and project conditions. Your inquiry email will automatically include the page you are viewing so our team can understand the exact product, technology or reference that led to your request.

  • Feedwater source / available analysis
  • Design flow or required production capacity
  • Target product-water quality or process duty
  • Project country, operating conditions and delivery target
Inquiry context Current page details will be attached automatically.