FENIGAL-FG Water Technologies
Tel: +86-13646187144 [email protected] Industrial Water Systems · Membranes · EDI · Desalination
FENIGAL-FG Water Technologies Wuxi Fenigal · Industrial Water Division
Translate this website

Google Translate is loaded only when you open this panel, reducing unnecessary requests and layout work during the first page load.

Loading language options…
Request Quote

Ultrafiltration (UF)

Professional Product Detail

DuPont IntegraTec XP 51 IG Pressurized PVDF Ultrafiltration Module, 51 m² Membrane Area

1. Product OverviewThe DuPont™ IntegraTec™ XP 51 IG is a pressurized, hollow-fiber ultrafiltration (UF) module with a hydrophilic PVDF membrane. It provides filtration for industrial utility water, wastewater reuse and municipal wastewater applications, as well as reverse osmosis (RO) pretre

Category: Ultrafiltration (UF)
DuPont IntegraTec XP 51 IG Pressurized PVDF Ultrafiltration Module, 51 m² Membrane Area

1. Product Overview

 The DuPont™ IntegraTec™ XP 51 IG is a pressurized, hollow-fiber ultrafiltration (UF) module with a hydrophilic PVDF membrane. It provides filtration for industrial utility water, wastewater reuse and municipal wastewater applications, as well as reverse osmosis (RO) pretreatment. Its short module design is suited to height-restricted and containerized installations.

ScreenShot_2026-11-04_133053_386.jpg

2. PRODUCT SPECIFICATIONS

Item

Specification

Model

DuPont™ IntegraTec™ XP 51 IG

Part number / GMID

12091623

Membrane type

Hollow fiber

Membrane material

Polyvinylidene fluoride (PVDF)

Other wetted components

Polyurethane, polyethylene and polyamide

Filtration mode

Outside-in, pressurized

Operating process

Dead-end

Approximate membrane pore size

0.03 μm

Active membrane area

51 m² (549 ft²)

Overall module length

1,860 ± 3 mm (73.2 ± 0.1 in)

Module diameter

225 mm (8.9 in)

Feed / filtrate port

DN50, 51 mm (2 in)

Empty weight

48 kg (106 lb)

Filled weight

83 kg (183 lb)

Shipping weight

60 kg (132 lb)

3. OPERATING PARAMETERS

Parameter

Value / Range

Operating temperature

1–40 °C (34–104 °F)

Operating pH

2–11

Cleaning pH

2–12

Typical filtration transmembrane pressure (TMP)

0.4–1.5 bar (5.8–21.8 psi)

Typical backwash TMP

0.6–2.0 bar (8.7–29.0 psi)

Backwash method

Air scour with liquid backwash

Typical backwash flux

100 L/(m²·h)

Typical backwash flow

5.1 m³/h

Maximum inlet pressure

6.25 bar (90.7 psi) at 20 °C

Maximum filtration TMP

2.1 bar (30.5 psi)

Maximum backwash TMP

2.5 bar (36 psi)

Maximum filtration flux

110 L/(m²·h)

Maximum filtration flow

5.6 m³/h

Maximum backwash flux

120 L/(m²·h)

Maximum particle size

300 μm

Maximum pressure change rate

0.5 bar/s (7.3 psi/s)

Maximum cumulative NaOCl exposure

≤ 1,500,000 ppm·h

Recommended maximum instantaneous NaOCl exposure

2,000 ppm

Avoid abrupt pressure changes during startup, operation, shutdown and cleaning. Refer to the applicable DuPont process and design manual for detailed operating guidance.

4. Key Features & Benefits

  • Hydrophilic PVDF hollow fibers: The membrane has an approximate pore size of 0.03 μm. The data sheet lists a high log removal rate for colloidal particles, bacteria and viruses.

    51 m² active membrane area: Provides a defined membrane area for system sizing and module selection.

  • Open-platform design: Designed to fit customer-built skids.

  • Short module format: Suited to height-restricted or containerized installations.

  • Air-scour backwash: Supports a backwash process combining air scouring with liquid backwash.

5. Key Applications

  • Industrial utility water filtration

  • Industrial wastewater reuse

  • Municipal wastewater filtration

  • Reverse osmosis pretreatment

ScreenShot_2026-11-02_170038_316 (1).jpg


Project Inquiry · Technical & Commercial

Send Your Water Treatment Requirement

Tell us the feedwater, required capacity, target water quality and project conditions. Your inquiry email will automatically include the page you are viewing so our team can understand the exact product, technology or reference that led to your request.

  • Feedwater source / available analysis
  • Design flow or required production capacity
  • Target product-water quality or process duty
  • Project country, operating conditions and delivery target
Inquiry context Current page details will be attached automatically.