Ultrafiltration (UF)
DuPont™ IntegraTec™ XP 77 IG Pressurized PVDF UF Module, 77 m² Membrane Area
1. Product OverviewThe DuPont™ IntegraTec™ XP 77 IG is a pressurized PVDF hollow-fiber ultrafiltration module for open-platform skids. Its out-in, dead-end filtration is specified for industrial utility water, industrial wastewater reuse, municipal wastewater filtration, and reverse osmosis (RO) p
1. Product Overview
The DuPont™ IntegraTec™ XP 77 IG is a pressurized PVDF hollow-fiber ultrafiltration module for open-platform skids. Its out-in, dead-end filtration is specified for industrial utility water, industrial wastewater reuse, municipal wastewater filtration, and reverse osmosis (RO) pretreatment.

2. PRODUCT SPECIFICATIONS
Item | Specification |
Model | DuPont™ IntegraTec™ XP 77 IG |
Filtration mode | Out-in pressurized |
Membrane type | Hollow fiber |
Membrane material | PVDF (polyvinylidene fluoride) |
Membrane pore size | 0.03 μm |
Operating process | Dead-end |
Other wetted module components | Polyurethane, uPVC, EPDM, and ABS |
Active membrane area | 77 m² |
Overall module length (L) | 2,360 ± 3.0 mm |
Module diameter (D) | 225 mm |
Module width (W1 / W2) | 180 mm / 342 mm |
Feed / filtrate port | DN50 (51 mm) |
Shipping weight | 73 kg |
Empty weight | 61 kg |
Filled weight | 100 kg |

3. OPERATING PARAMETERS
Parameter | Value / Range |
Suggested operating temperature | 1–40 °C |
Operating pH | 2–11 |
Cleaning pH | 2–12 |
Typical filtration trans-membrane pressure (TMP) | 0.4–1.5 bar |
Typical backwash TMP | 0.6–2.0 bar |
Backwash type | Air scour with liquid backwash |
Typical backwash flux | 100 L/(m²·h) |
Typical backwash flow | 7.7 m³/h |
Maximum inlet pressure (at 20 °C) | 6.25 bar |
Maximum filtration TMP | 2.1 bar |
Maximum backwash TMP | 2.5 bar |
Maximum filtration flux | 110 L/(m²·h) |
Maximum filtration flow | 8.5 m³/h |
Maximum backwash flux | 120 L/(m²·h) |
Maximum allowable rate of pressure change | 0.5 bar/s |
Maximum particle size | 300 μm |
NaOCl exposure | ≤1,500,000 ppm × h |
Recommended maximum instantaneous NaOCl exposure | 2,000 ppm |
Avoid abrupt pressure changes during start-up, operation, shutdown, cleaning, or other sequences.
Certified drinking-water modules require specific conditioning before producing potable water. Refer to the manufacturer’s process and design guidelines. Check local regulatory requirements and application status before use.
4. Key Features & Benefits
XP™ hydrophilic PVDF fiber: Provides resistance to fouling and chlorine, high log-removal rates for colloidal particulates, bacteria, and viruses, excellent filtration permeability, and easy cleaning and wetting.
Open-platform design: Designed to adapt to customer-built skids.
Optimized module design: Features a high active filtration area to maximize productivity, with high-recovery operation and high tolerance to air scouring.
Maintenance-cleaning protocol: The specified protocol is designed to reduce chemical consumption.
5. Key Applications
Industrial utility water
Industrial wastewater reuse
Municipal wastewater filtration
RO pretreatment

Send Your Water Treatment Requirement
Tell us the feedwater, required capacity, target water quality and project conditions. Your inquiry email will automatically include the page you are viewing so our team can understand the exact product, technology or reference that led to your request.
- Feedwater source / available analysis
- Design flow or required production capacity
- Target product-water quality or process duty
- Project country, operating conditions and delivery target