FENIGAL-FG Water Technologies
Tel: +86-13646187144 [email protected] Industrial Water Systems · Membranes · EDI · Desalination
FENIGAL-FG Water Technologies Wuxi Fenigal · Industrial Water Division
Translate this website

Google Translate is loaded only when you open this panel, reducing unnecessary requests and layout work during the first page load.

Loading language options…
Request Quote

Solution

Professional Product Detail

Semiconductor & Microelectronics: UPW Pretreatment with IntegraTec™ XP 77 IP

Industry context and the problemUltrapure water (UPW) is the primary cleaning medium in wafer fabrication, and sub-micron colloidal or microbial contamination directly threatens device yield. Conventional multimedia filtration is not an absolute barrier, so downstream RO and polishing IX bear the fu

Category: Solution
Semiconductor & Microelectronics: UPW Pretreatment with IntegraTec™ XP 77 IP

Industry context and the problem

Ultrapure water (UPW) is the primary cleaning medium in wafer fabrication, and sub-micron colloidal or microbial contamination directly threatens device yield. Conventional multimedia filtration is not an absolute barrier, so downstream RO and polishing IX bear the full contaminant load. Semiconductor fabs need a pressurized UF barrier with high packing density, validated log-reduction values, and chlorine tolerance for membrane maintenance — all in a module that fits existing skid envelopes.

DuPont solution: IntegraTec™ XP 77 IP

ParameterSpecification
ModelDuPont™ IntegraTec™ XP 77 (Open Platform, OP)
Part No. / GMID12091620
Membrane materialPVDF (hydrophilic XP™ fiber)
Nominal pore size0.03 μm (30 nm)
Active membrane area77 m² (829 ft²)
Filtration modeOutside-in, pressurized, dead-end
Module diameter225 mm (8.9″)
Module length (overall)2,363 ± 3 mm (93.0″)
Feed / filtrate portDN50 (51 mm / 2.0″)
Weight (empty / filled)61 kg / 100 kg (134 / 220 lbs)
Shipping weight73 kg (161 lbs)
Hold-up volume (CIP, feed side)37 L (9.8 gal)

Source: DuPont IntegraTec XP 77 product data sheet.

Performance and outcomes

In a full-scale direct potable reuse installation in Flanders, Belgium, IntegraTec XP 77 IP modules operate in two racks of 16 modules each, achieving >90% UF recovery at a filtrate flow of 71.4 m³/h and flux <40 LMH. The membranes carry NSF certification with a theoretical 6.3 log reduction value (LRV) for bacteria and 2 LRV for viruses; integrity is verified through automated pressure-hold testing, and backwash is performed with air scouring only, without chemicals, supplemented by a daily mini-CIP using NaOCl/NaOH or citric acid.

For semiconductor UPW pretreatment specifically, the XP 77’s combination of 77 m² per 8.9″ module and outside-in PVDF chemistry delivers the high area density and fouling resistance needed to stabilize RO feed quality and extend downstream IX run lengths.

What this means for buyers

The XP 77 IP is the highest-area module in the 8-inch pressurized PVDF class, reducing module count and skid footprint for large UPW pretreatment trains. Its open-platform design fits customer-built skids, and the XP fiber’s chlorine resistance supports maintenance cleaning protocols with reduced chemical consumption.


Project Inquiry · Technical & Commercial

Send Your Water Treatment Requirement

Tell us the feedwater, required capacity, target water quality and project conditions. Your inquiry email will automatically include the page you are viewing so our team can understand the exact product, technology or reference that led to your request.

  • Feedwater source / available analysis
  • Design flow or required production capacity
  • Target product-water quality or process duty
  • Project country, operating conditions and delivery target
Inquiry context Current page details will be attached automatically.