DuPont™ IntegraTec™ SFP-2660 & SFD-2660 Open-Platform PVDF Ultrafiltration Modules, 33 m² Membrane Area

1. Product OverviewDuPont™ IntegraTec™ SFP-2660 and SFD-2660 are pressurized, out-in hollow-fiber ultrafiltration modules for open-platform systems. They use PVDF membranes with a 0.03 μm pore size and 33 m² of active membrane area. Applications include industrial utility water, industrial waste

Category: Ultrafiltration (UF)
DuPont™ IntegraTec™ SFP-2660 & SFD-2660 Open-Platform PVDF Ultrafiltration Modules, 33 m² Membrane Area

1. Product Overview

DuPont™ IntegraTec™ SFP-2660 and SFD-2660 are pressurized, out-in hollow-fiber ultrafiltration modules for open-platform systems. They use PVDF membranes with a 0.03 μm pore size and 33 m² of active membrane area. Applications include industrial utility water, industrial wastewater reuse, municipal wastewater reuse, municipal drinking water, and RO/NF pretreatment.


image.png


2. PRODUCT SPECIFICATIONS

Item

Specification

Brand

DuPont™ IntegraTec™

Models

SFP-2660 and SFD-2660

Part No. / GMID

SFP-2660: 10380855; SFD-2660: 10380857

Module Type

Open-platform PVDF ultrafiltration module

Filtration Mode

Out-in, pressurized

Membrane Type

Hollow fiber

Membrane Material

PVDF (Polyvinylidene Fluoride)

Membrane Pore Size

0.03 μm 

Module Operating Process

Dead-end

Active Membrane Area

33 m² (355 ft²)

Module Length Overall (L)

1,838 ± 3.0 mm (72.4 ± 0.1 in)

Module Length (L1)

1,500 ± 1.5 mm (59.1 ± 0.1 in)

Module Length (L2)

1,613 ± 3.0 mm (63.5 ± 0.1 in)

Module Length (L3)

1,713 ± 3.0 mm (67.4 ± 0.1 in)

Module Diameter (D)

165 mm (6.5 in)

Module Width (W1)

125 mm (4.9 in)

Module Width (W2)

250 mm (9.8 in)

Shipping Weight

30 kg (66 lb)

Empty Weight

25 kg (55 lb)

Filled Weight

41 kg (90 lb)

Feed Hold-Up Volume, CIP

14 L (3.7 gal)

Membrane Structure Hold-Up Volume, CIP

6 L (1.6 gal)

Filtrate Hold-Up Volume, CIP

4 L (1.0 gal)

Air Port

G3/8"

Feed Port

DN50

Filtrate Port

DN50

Concentrate Port

DN32

Other Wetted Module Components

Polyurethane, uPVC, EPDM, and ABS


image.png


3. OPERATING PARAMETERS

 Suggested Operating Conditions

Parameter

Value / Range

Operating Temperature

1–40 °C (34–104 °F)

Operating pH

2–11

Cleaning pH

2–12

Typical Filtration TMP

0.4–1.5 bar (5.8–21.8 psi)

Typical Backwash TMP

0.6–2.0 bar (8.7–29.0 psi)

Backwash Type

Air scour with liquid backwash

Typical Backwash Flux

40–100 L/(m²·h) (23.5–58.8 gfd)

Typical Backwash Flow

1.3–3.3 m³/h (5.8–14.6 gpm)

Maximum Operating Limits

Parameter

Value / Range

Maximum Rate of Pressure Change

0.5 bar/s (7.3 psi/s)

Maximum Inlet Pressure

6.25 bar (90.7 psi) at 20 °C

Maximum Filtration TMP

2.1 bar (30.5 psi)

Maximum Backwash TMP

2.5 bar (36 psi)

Maximum Filtration Flux

110 L/(m²·h) (64.5 gfd)

Maximum Filtration Flow

3.6 m³/h (16.0 gpm)

Maximum Backwash Flux

120 L/(m²·h) (70.6 gfd)

Recommended Maximum Instantaneous NaOCl Exposure

2,000 ppm

Maximum NaOCl Exposure

≤1,500,000 ppm·h

Maximum Particle Size

300 μm

4. Key Features & Benefits

  • PVDF hollow-fiber membrane: The PVDF fiber has high strength and excellent flexibility, ensuring long-lasting durability.

  • 0.03 μm nominal pore size: Effectively removes colloidal particulate, bacteria, and virus.

  • Compact module design: Suits small-capacity installations.

  • High operation recovery and air-scouring tolerance: Supports module operation with air scouring and liquid backwash.

  • Open-platform design: Adapts to customer-built skids.

  • Easy installation and low maintenance.

5. Key Applications

  • Industrial utility water

  • Industrial wastewater reuse

  • Municipal wastewater reuse

  • Municipal drinking water

  • RO/NF pretreatment

69329c8fedd04ea5b8245c082093a5b9.jpg

Project Inquiry · Technical & Commercial

Send Your Water Treatment Requirement

Tell us the feedwater, required capacity, target water quality and project conditions. Your inquiry email will automatically include the page you are viewing so our team can understand the exact product, technology or reference that led to your request.

  • Feedwater source / available analysis
  • Design flow or required production capacity
  • Target product-water quality or process duty
  • Project country, operating conditions and delivery target
Inquiry context Current page details will be attached automatically.