Ultrafiltration (UF)
DuPont™ IntegraTec™ SFP-2660 & SFD-2660 Open-Platform PVDF Ultrafiltration Modules, 33 m² Membrane Area
1. Product OverviewDuPont™ IntegraTec™ SFP-2660 and SFD-2660 are pressurized, out-in hollow-fiber ultrafiltration modules for open-platform systems. They use PVDF membranes with a 0.03 μm pore size and 33 m² of active membrane area. Applications include industrial utility water, industrial waste
1. Product Overview
DuPont™ IntegraTec™ SFP-2660 and SFD-2660 are pressurized, out-in hollow-fiber ultrafiltration modules for open-platform systems. They use PVDF membranes with a 0.03 μm pore size and 33 m² of active membrane area. Applications include industrial utility water, industrial wastewater reuse, municipal wastewater reuse, municipal drinking water, and RO/NF pretreatment.

2. PRODUCT SPECIFICATIONS
Item | Specification |
Brand | DuPont™ IntegraTec™ |
Models | SFP-2660 and SFD-2660 |
Part No. / GMID | SFP-2660: 10380855; SFD-2660: 10380857 |
Module Type | Open-platform PVDF ultrafiltration module |
Filtration Mode | Out-in, pressurized |
Membrane Type | Hollow fiber |
Membrane Material | PVDF (Polyvinylidene Fluoride) |
Membrane Pore Size | 0.03 μm |
Module Operating Process | Dead-end |
Active Membrane Area | 33 m² (355 ft²) |
Module Length Overall (L) | 1,838 ± 3.0 mm (72.4 ± 0.1 in) |
Module Length (L1) | 1,500 ± 1.5 mm (59.1 ± 0.1 in) |
Module Length (L2) | 1,613 ± 3.0 mm (63.5 ± 0.1 in) |
Module Length (L3) | 1,713 ± 3.0 mm (67.4 ± 0.1 in) |
Module Diameter (D) | 165 mm (6.5 in) |
Module Width (W1) | 125 mm (4.9 in) |
Module Width (W2) | 250 mm (9.8 in) |
Shipping Weight | 30 kg (66 lb) |
Empty Weight | 25 kg (55 lb) |
Filled Weight | 41 kg (90 lb) |
Feed Hold-Up Volume, CIP | 14 L (3.7 gal) |
Membrane Structure Hold-Up Volume, CIP | 6 L (1.6 gal) |
Filtrate Hold-Up Volume, CIP | 4 L (1.0 gal) |
Air Port | G3/8" |
Feed Port | DN50 |
Filtrate Port | DN50 |
Concentrate Port | DN32 |
Other Wetted Module Components | Polyurethane, uPVC, EPDM, and ABS |

3. OPERATING PARAMETERS
Suggested Operating Conditions
Parameter | Value / Range |
Operating Temperature | 1–40 °C (34–104 °F) |
Operating pH | 2–11 |
Cleaning pH | 2–12 |
Typical Filtration TMP | 0.4–1.5 bar (5.8–21.8 psi) |
Typical Backwash TMP | 0.6–2.0 bar (8.7–29.0 psi) |
Backwash Type | Air scour with liquid backwash |
Typical Backwash Flux | 40–100 L/(m²·h) (23.5–58.8 gfd) |
Typical Backwash Flow | 1.3–3.3 m³/h (5.8–14.6 gpm) |
Maximum Operating Limits
Parameter | Value / Range |
Maximum Rate of Pressure Change | 0.5 bar/s (7.3 psi/s) |
Maximum Inlet Pressure | 6.25 bar (90.7 psi) at 20 °C |
Maximum Filtration TMP | 2.1 bar (30.5 psi) |
Maximum Backwash TMP | 2.5 bar (36 psi) |
Maximum Filtration Flux | 110 L/(m²·h) (64.5 gfd) |
Maximum Filtration Flow | 3.6 m³/h (16.0 gpm) |
Maximum Backwash Flux | 120 L/(m²·h) (70.6 gfd) |
Recommended Maximum Instantaneous NaOCl Exposure | 2,000 ppm |
Maximum NaOCl Exposure | ≤1,500,000 ppm·h |
Maximum Particle Size | 300 μm |
4. Key Features & Benefits
PVDF hollow-fiber membrane: The PVDF fiber has high strength and excellent flexibility, ensuring long-lasting durability.
0.03 μm nominal pore size: Effectively removes colloidal particulate, bacteria, and virus.
Compact module design: Suits small-capacity installations.
High operation recovery and air-scouring tolerance: Supports module operation with air scouring and liquid backwash.
Open-platform design: Adapts to customer-built skids.
Easy installation and low maintenance.
5. Key Applications
Industrial utility water
Industrial wastewater reuse
Municipal wastewater reuse
Municipal drinking water
RO/NF pretreatment

Send Your Water Treatment Requirement
Tell us the feedwater, required capacity, target water quality and project conditions. Your inquiry email will automatically include the page you are viewing so our team can understand the exact product, technology or reference that led to your request.
- Feedwater source / available analysis
- Design flow or required production capacity
- Target product-water quality or process duty
- Project country, operating conditions and delivery target