Rogen-C
Containerized Brackish Water Reverse Osmsosis (BWRO) System is a containerized desalination solution, with most parts installed into 1 or 2 containers, and fresh water capacity of 100 to 2,000 m® 3/day (4,080-83,270 liters/hour).
The water intake recommendation, extra pre-treatment and post-treatment customizing, installation supervision service, commissioning services could be provided by the QT technical team upon request.
Note: the comparison is calculated roughly on the basis of 1,000m³/days water production.
System characteristics
Quick installation and commissioning: Most of the installation is completed before delivery
Quick installation and commissioning: Most of the installation is completed before delivery
Better corrosion resistant: Using Sch10 SS316 high pressure pipe and fittings, and heavy duty paint
Low energy consumption: Using high-efficiency high pressure pump
E3 motors and low energy-consumption RO membrane
Fast restoring: In case of malfunction, the whole system can be restored quickly by using standard parts
Better filtration: 3 steps filtering process including sand filter, pre-filter and main filter to ensure better protection for high pressure pump, energy recovery device and RO membrane
Long service life: The wet parts are made of duplex, SS904L, UPVC or other plastics and the heavy-duty marine paint is used for frame and container
Upgrade on demand: We can add sensors according to customer needs, collect data remotely and provide operational consulting service
Extensive applications
Technical specifications
Notes:
1)The rated product flow and rated recovery rate are based on the design feed (4,000 ppm, 20°C brackish water), other recovery rate could be reachable, contact us for details
2)The normal operating system pressure shall be higher than the minimum system pressure above. Higher maximum system pressure could be applicable upon request
3)The dry weight excludes water (operating or other)
4)The rated power and energy consumption calculation are based on a design feed (4,000 ppm, 20°C brackish water), the rated flow and rated recovery rate. The calculation include the power of feed pump, high pressure pump (HPP), inter-stage boost pump, cleaning in place (CIP) pump, dosing pumps, but exclude the power of intake pump, product distribution pump and air conditioner
5)Installed power includes feed pump, HPP, inter-stage boost pump, CIP pump, dosing pump and lights.