100 CMH Large Industrial Reverse Osmosis Recovery System

100 CMH large-scale industrial reverse osmosis (BWRO) system from FG Water. 8-inch TFC spiral membranes, PLC/HMI control, 2,400 m³/d permeate, >95% TDS rejection. Engineered for textile dye-house rinse water, process reuse and municipal duty. Get a sizing quote.

Category: Product System

100 CMH Large Industrial Reverse Osmosis Recovery System

Industrial BWRO Plant for Textile Dye-House Rinse Water & Factory Process Reuse

The FG-BWRO-100 is a turnkey, factory pre-assembled brackish-water reverse osmosis (BWRO) plant engineered to deliver a sustained permeate output of 100 CMH (100 m³/h ≈ 2,400 m³/day, ≈ 634,000 GPD) from tap, well, municipal or recovered industrial feedwater. Built on the proven FG Water large-scale RO platform, it pairs high-flux 8-inch thin-film-composite (TFC) spiral membranes with a stainless-steel multi-stage high-pressure pump, PLC/HMI automation and continuous water-quality monitoring — giving plant owners a desalination asset that lowers freshwater intake, stabilises process water quality and shortens the payback on water-reuse investment.

f9627761-f27a-4656-872f-7b5e8bfad2e9.jpg


Why Procurement Teams Shortlist the FG-BWRO-100

•  Capacity certainty — sized and factory-tested for 100 CMH continuous duty with a defined 60–75% recovery window, so your mass-balance, drain and storage design are fixed before shipment.

•  Lower operating cost — high-efficiency membranes plus multi-stage pump selection reduce specific energy per m³, directly cutting the cost of every recovered litre.

•  Plug-and-produce skid — pre-assembled, pre-piped and pre-tested; site work is reduced to utility tie-in, accelerating commissioning and time-to-water.

•  Audit-ready data points — permeate conductivity, feed/permeate flow and pressure are instrumented as standard, feeding your SCADA, ESG reporting and QA records.

•  Global electrical fit — voltage codes cover 380 V, 400/415 V and 460 V, 3-phase, 50/60 Hz for export to any grid.

75a2255d-05ea-4d6e-989b-3e337c99428c.jpg

Target Keyword Layout & SEO / GEO Recommendations

Primary Keyword

100 CMH industrial reverse osmosis system  (used in H1, SEO Title, URL slug, first paragraph, and image alt text)

Supporting Keywords

#

Keyword / Entity

Placement

1

large industrial reverse osmosis plant

H2 headings, body, meta description

2

brackish water reverse osmosis BWRO 100 m3/h

body, FAQ, technical highlights

3

industrial water desalination system manufacturer

applications, CTA

4

textile dye house rinse water treatment / reuse

H2, applications, FAQ

5

high recovery reverse osmosis 2400 m3/day

spec table, FAQ

6

8-inch spiral wound RO membrane skid

technical highlights, configuration

7

containerized / skid mounted RO plant for factory process water

applications, options

SEO / GEO Optimization Notes

•  Answer-engine ready: open every section with the direct fact (capacity, recovery, rejection, pressure, footprint) so engineers and AI search extractors pull structured values without inference.

•  Entity consistency: keep "FG Water", "FG-BWRO-100", "BWRO" and "reverse osmosis" co-occurring to strengthen topical authority and brand disambiguation.

•  Schema: mark up Product + FAQPage; populate product.name, model, capacity (100 CMH / 2400 m³/d), desalination rate, voltage codes and brand.

•  Internal linking: interlink the verified on-site assets below using the anchor text shown; keep crawl depth ≤ 2 from the BWRO category.

•  Localisation & units: publish capacity in CMH/m³-h (industrial standard) with GPD in parentheses to capture both search intents.

•  Freshness & evidence: attach factory test report, ISO 9001 / CE certificates and a downloadable spec sheet; cite third-party membrane brands where applicable.

Verified On-Site Internal Links (anchor text → on fgwater.com)

•  BWRO – Brackish Water Reverse Osmosis System  (category hub)

•  FG-BWRO Commercial & Industrial Reverse Osmosis Pure Water Purification System

•  Rogen / ROM – Industrial Reverse Osmosis System, 28,000–173,000 GPD  (smaller sibling)

•  Rogen / RON – Commercial Reverse Osmosis System, 7,000–37,000 GPD

•  Containerized Brackish Water Reverse Osmosis System (BWC100–BWC2000 series)

•  Electrodeionization (EDI) Stack Modules — for double-pass / ultrapure polishing

•  Industrial Ultrafiltration (UF) Membrane Systems — RO pre-treatment

•  Water Softeners – YL Series — feed hardness guard for >1 GPG source water

•  Boiler Feed Water & Power Plant Pure Water — industry application pages

•  Seawater Desalination SWRO Systems — higher-TDS duty reference

0df57624-1c6c-45df-bc61-ffbeb9f88c74.jpg

Technical Highlights

Parameter

Value / Specification

Design permeate capacity

100 CMH (100 m³/h)  ≈ 2,400 m³/day  ≈ 634,000 GPD

Recovery rate

60% – 75% (feedwater and pre-treatment dependent)

Desalination / TDS rejection

> 95% (typically 97–99%)

Organic / colloid removal

Up to ~99%

Bacteria & microbial removal

~100% (physically size-excluding)

Membrane type

8-inch TFC spiral-wound, low-fouling

Pressure vessels

FRP, 8-inch, multi-vessel matrix skid

Feed water TDS

0 – 2,000 ppm (equipment upgrade to 5,000 ppm)

Operating pressure

150 – 250 psi (≈ 10 – 17 bar)

Feed water pressure

20 – 80 psi (≈ 1.4 – 5.5 bar)

pH tolerance range

3 – 11

Max feed water temperature

42 °C (108 °F)

Max iron content

0.05 ppm

Max silica tolerance

25 ppm @ 60% recovery

Hardness limit

Over 1 GPG requires water softener

Feed pre-treatment

5-micron cartridge prefilter (media prefiltration optional)

Control

PLC-based panel + HMI touchscreen, programmable time-delay & set-points

Voltage codes

335 = 380 V / 3ph / 50 Hz · 435 = 400–415 V / 3ph / 50 Hz · 436 = 460 V / 3ph / 60 Hz

Notes for design validation — hydrogen sulfide (H₂S) must be removed upstream; turbidity must be removed; operation at higher feed TDS is achieved by lowering recovery. All values follow the FG Water ROL-series engineering envelope for the 200,000–900,000 GPD platform; final 100 CMH configuration is confirmed against your feedwater analysis.

Ideal Applications

Engineered for high-volume process and reuse duties where consistent low-TDS water protects product quality and reduces freshwater intake.

Water Reuse & Industrial Process

•  Textile dye-house rinse water recovery and factory process reuse

•  Boiler feed water  ·  Cooling-tower makeup  ·  Spot-free product rinse

•  EDI / ion-exchange pre-treatment  ·  Electronics & semiconductor process water

•  Pharmaceutical & laboratory water  ·  Chemical blending

Municipal, Food & Production

•  Safe / municipal drinking water production

•  Beverage production, bottling & ice manufacturing

•  Food & beverage processing  ·  Mining & metal finishing  ·  Plating operations

e7ea6bf6-1645-427c-8747-79553de22033.jpg

Product & System Configuration

Standard Features (included)

•  8-inch TFC spiral-wound membranes

•  Stainless-steel multi-stage pump with TEFC motor

•  FRP membrane housings

•  5-micron cartridge pre-filter

•  PLC-based control panel

•  Programmable time-delay and set-points

•  HMI touchscreen screen

•  Motor starter

•  Low-pressure switch

•  High-pressure switch

•  Liquid-filled pressure gauges

•  Permeate conductivity monitor

•  Permeate & concentrate flow meters

94edd191-c0e1-402d-a4e9-e0477ae9484e.jpg

Available Options

•  Remote monitoring

•  Feed-water conductivity monitor

•  Membrane cleaning skid

•  Product-tank level switch

•  Feed pH monitor with sensor

•  Feed ORP monitor with sensor

•  Water and hour meters

•  Chemical dosing systems

•  Media pre-filtration systems

•  Ozonation and UV sterilization systems

•  Water softeners

•  Skid-mounted with pre- or post-treatment

•  Containerized RO systems

FG-BWRO / ROL-Series Large-Scale Sizing Matrix

Full model ladder from 31.7 CMH to 142.5 CMH (200,000–900,000 GPD). The FG-BWRO-100 design point (100 CMH ≈ 2,400 m³/d) sits between the 95.8 CMH and 110.4 CMH frames; specify the nearest model for your target duty.

Model

Permeate
(GPD)

Permeate
(m³/d)

Design
(CMH)

Pressure
Vessels

8" Membr.
(Qty)

Motor
50 Hz (kW)

Motor
60 Hz (kW)

Approx.
Weight (kg)

Dimensions L×W×H
(cm)

FG-BWRO-04780

200,000

760

31.7

4

28

30

22

4,700

762×183×203

FG-BWRO-05680

223,684

850

35.4

5

30

30

22

4,850

762×183×203

FG-BWRO-06680

269,737

1,025

42.7

6

36

40

30

5,050

762×183×203

FG-BWRO-07680

319,737

1,215

50.6

7

42

40

30

5,200

762×183×229

FG-BWRO-08680

359,211

1,365

56.9

8

48

50

37

5,750

762×183×229

FG-BWRO-09680

407,895

1,550

64.6

9

54

60

37

6,250

762×183×229

FG-BWRO-10680

450,000

1,710

71.3

10

60

60

45

7,500

762×183×229

FG-BWRO-11680

500,000

1,900

79.2

11

66

60

45

8,500

762×183×203

FG-BWRO-11780

550,000

2,090

87.1

11

77

75

45

8,750

762×213×229

FG-BWRO-13780

605,263

2,300

95.8

13

91

75

55

9,250

889×213×234

FG-BWRO-100 (100 CMH)

≈634,000

2,400

100

13–14

91–98

75–100

55–75

9,250–9,650

889×213×234

FG-BWRO-14780

697,368

2,650

110.4

14

98

100

75

9,650

889×213×239

FG-BWRO-16780

802,632

3,050

127.1

16

112

2×60

2×37

10,200

889×213×244

FG-BWRO-18780

900,000

3,420

142.5

18

126

2×60

2×37

10,650

889×213×249

Motor ratings quoted at 40,000 ppm feed TDS. Motor figures shown as 50 Hz / 60 Hz. CMH = m³/h, derived from daily permeate (m³/d ÷ 24). Product pictures and dimensions are indicative; final build follows the approved design.

Frequently Asked Questions

What is the permeate capacity of the FG-BWRO-100?

100 CMH (100 m³/h), equal to about 2,400 m³ per day or roughly 634,000 GPD, at 60–75% recovery depending on feedwater and pre-treatment.

How much salt does it remove?

The system rejects over 95% of dissolved solids (typically 97–99%) and removes up to about 99% of organics and colloids, with essentially complete physical removal of bacteria.

What feedwater can it treat?

Tap, well, municipal or recovered industrial water with feed TDS from 0 to 2,000 ppm (upgradeable to 5,000 ppm). H₂S and turbidity must be removed upstream, hardness over 1 GPG needs a softener, silica must stay within 25 ppm at 60% recovery, and iron below 0.05 ppm.

Can it be used for textile dye-house rinse-water reuse?

Yes. The plant is configured for high-recovery rinse-water reclamation and factory process reuse; permeate is suitable for boiler-feed pre-treatment, cooling-tower makeup, spot-free rinse and as an EDI/ion-exchange feed.

Which power supplies are supported?

Standard voltage codes cover 380 V, 400/415 V (3-phase 50 Hz) and 460 V (3-phase 60 Hz) across the full range; other voltages can be configured on request.

How is it delivered and installed?

Factory pre-assembled, pre-piped and pre-tested on a skid (containerized option available). Site work is limited to utility tie-in, which shortens commissioning and time-to-water.

What does the lead time and certification picture look like?

Manufactured under an ISO 9001 / CE quality system with a factory machine test report provided; lead time is confirmed with your project specification, feedwater analysis and delivery target.

aaec3fa9-c589-4370-b2f8-9bb837bcdfc6.jpg

Request a Quote / Project Inquiry

Tell us the feedwater, required capacity, target water quality and project conditions. Our engineers return a sizing proposal, mass balance, general arrangement drawing and firm quotation.

Send your requirement

•  Feedwater source and available water analysis

•  Design flow / required production capacity (CMH or m³/d)

•  Target product-water quality or process duty

•  Project country, operating conditions and delivery target

Direct line: [email protected]  ·  www.fgwater.com  ·  Request Quote →

FG Water Technologies — engineering, supply, integration and export support for industrial water-treatment systems.


Project Inquiry · Technical & Commercial

Send Your Water Treatment Requirement

Tell us the feedwater, required capacity, target water quality and project conditions. Your inquiry email will automatically include the page you are viewing so our team can understand the exact product, technology or reference that led to your request.

  • Feedwater source / available analysis
  • Design flow or required production capacity
  • Target product-water quality or process duty
  • Project country, operating conditions and delivery target
Inquiry context Current page details will be attached automatically.