Product System
FG Water FG-BWRO Series Skid-Mounted BWRO System 8–13 m³/h
FG Water FG-BWRO-824/826 skid-mounted BWRO systems deliver 8–13 m³/h of permeate for industrial water treatment, boiler feedwater pretreatment, and mid-size manufacturing applications.
FG Water FG-BWRO Series Skid-Mounted BWRO System 8–13 m³/h
Product Overview
The FG Water FG-BWRO Series is a range of standard skid-mounted brackish water reverse osmosis systems for industrial water treatment, boiler feedwater pretreatment, cooling-tower make-up water, process water, food and beverage water treatment, and mid-size manufacturing applications.
Each system is factory-assembled, factory-tested and delivered on a standardised scope, ready for container or break-bulk shipment. The FG-BWRO-824 and FG-BWRO-826 are rated at 8 m³/h and 12.9 m³/h of nominal permeate (product-water) flow respectively, removing hardness ions and dissolved solids before water enters boilers, heat exchangers and cooling circuits.
Key Benefits
· Standardised scope reduces quotation time and delivery risk
· Factory assembly and factory acceptance testing before shipment
· PLC automation with sensor protection as standard, not an optional extra
· SS304 stainless steel frame and corrosion-resistant wetted piping
· Consistent low permeate hardness supports stable steam quality and less chemical cleaning
· Flexible voltage, skid material and automation options for global projects
· Spare parts and technical support available for long-term operation
Model Selection
The FG-BWRO Series covers two standard nominal permeate capacities. Flow values below refer to permeate (product-water) flow, not feedwater flow.
Model | Nominal permeate flow | Equivalent | Salt rejection | Membrane elements (nominal) |
FG-BWRO-824 | 8 m³/h | 54,800 GPD | >97% | 8 |
FG-BWRO-826 | 12.9 m³/h | 82,200 GPD | >97% | 12 |
Technical Specifications
Attribute | FG-BWRO-824 | FG-BWRO-826 |
Nominal permeate flow | 8 m³/h / 54,800 GPD | 12.9 m³/h / 82,200 GPD |
Membrane elements, nominal | 8 | 12 |
Power | 5 kW, 5.5 kW rated | To be confirmed |
Frame material | SS304 stainless steel frame | SS304 stainless steel frame |
Control system | PLC + touch-screen HMI | PLC + touch-screen HMI |
Footprint | 0.8 × 2.5 × 1.9 m | To be confirmed |
Weight | 550 kg | To be confirmed |
Salt rejection | >97% | >97% |
Design recovery rate is typically 65–75% with a concentrate ratio of approximately 3:1 to 4:1. Operating pressure is approximately 8–15 bar depending on feedwater TDS and temperature. Final configuration is confirmed from feedwater analysis and engineering review.
Feedwater Requirements
Parameter | Verified limit |
SDI, Silt Density Index | <3 |
Turbidity | <1 NTU |
Feed temperature | 5–40 °C |
pH tolerance | 3–11 |
Iron | <0.05 mg/L |
Maximum free chlorine | 0 ppm |
Salt rejection | >97% |
Standard TDS application window | ≤2,000 mg/L |
Process Configuration
Pretreatment
· Feedwater pump and buffer tank, sized to the specified design flow
· Multi-media filter (MMF) for turbidity and suspended-solids removal
· Activated carbon filter (ACF) for chlorine, colour and organic removal
· Water softener with resin bed and brine tank for hardness ion exchange (when specified)
· 5 µm / 20-micron cartridge filtration as RO feed protection
High-Pressure RO Unit
· High-pressure vertical multistage centrifugal pump, VFD-ready
· FRP or stainless steel pressure vessels with spiral-wound BWRO membrane elements
· Membrane selection based on feedwater TDS, hardness and recovery target
· Antiscalant dosing (when specified)
· Concentrate flow control valve and permeate flow regulator
Instrumentation and Control
· Gauge panel: raw water, feed, concentrate, permeate and CIP pressures
· Conductivity and flow meters on feed, permeate and reject lines
· Low-pressure switch, high-pressure switch and permeate conductivity monitor
· PLC automatic control with touch-screen HMI (standard); manual option available
Cleaning-In-Place (CIP)
· Semi-automatic CIP pump, tank and cartridge filter
· Full-automatic CIP option integrated with PLC control and conductivity monitoring
Skid, Piping and Electrical
· SS304 stainless steel skid frame, epoxy painted or polished
· SS304 or SS316L wetted piping with EPDM or Viton seals
· Control panel with reputable-brand electrical components
· Design voltage: 400V/50Hz/3P or 460V/60Hz/3P; other voltages available on request
Standardised Flow Sequence
· Raw water tank / feed source
· Feedwater pump → multi-media filter → activated carbon filter
· Water softener (optional, based on hardness level)
· 5 µm cartridge filter → high-pressure pump → BWRO membrane array
· Permeate tank → distribution pump → point of use
· Reject stream → drain or secondary recovery
· CIP skid → CIP tank → membrane cleaning loop
· PLC panel: automatic start/stop, high/low pressure protection, permeate conductivity monitoring, dry-run protection
Standard Scope
· Skid-mounted BWRO unit with high-pressure pump and membrane array
· Cartridge filtration and instrumented gauge panel
· PLC automatic control with touch-screen HMI
· SS304 frame and wetted piping, factory-assembled and factory-tested
Optional Scope
· Water softener upstream of RO for high-hardness feedwater
· Antiscalant dosing system
· UV steriliser or ozone generator for permeate disinfection
· Full-automatic CIP system
· EDI module or mixed-bed polisher for high-purity permeate
· Alternative skid material and non-standard voltages
Typical Applications
· Boiler feedwater pretreatment for industrial steam boilers and thermal-oil systems
· Cooling-tower make-up water treatment to control hardness and scaling
· RO feedwater pretreatment where high hardness limits recovery
· Feedwater treatment for heat exchangers and condensate systems
· Food, beverage, textile, paper, chemical and light-industrial process water
· Water treatment skids for mining camps, industrial parks and EPC subcontracts
System Selection and Design Notes
BWRO reduces hardness and dissolved solids and is therefore a strong pretreatment stage for boiler feedwater. Whether the RO permeate alone meets a particular boiler's feedwater specification depends on boiler pressure and type, raw-water chemistry and the required post-treatment. BWRO should not be read as satisfying every boiler standard on its own.
Boiler / duty condition | Is BWRO permeate likely sufficient on its own | Typical additional treatment |
Low-pressure steam or hot-water boiler | Sometimes, subject to conductivity, alkalinity and silica limits | Degassing, pH adjustment, blowdown control |
Medium- to high-pressure boiler | Usually not on its own | Deaeration plus condensate polishing / demineralisation |
High-purity / low-conductivity systems | No | EDI or mixed-bed polishing to reach required conductivity |
High-silica or high-alkalinity feedwater | Requires special design | Chemical pretreatment and tailored membrane / recovery design |
The table reflects general boiler-water practice, not a claim about a specific site. Final configuration is set from boiler operating data and a feedwater analysis supplied with the enquiry.
Documentation and Quality Control
· Factory-assembled and factory-tested skid systems
· Factory acceptance testing available prior to shipment
· General arrangement drawings and P&ID available on request
· Final configuration, materials and documentation scope confirmed at the quotation stage
Frequently Asked Questions
What is the FG-BWRO Series?
The FG-BWRO Series is a standard skid-mounted brackish water reverse osmosis system for industrial water treatment and boiler feedwater pretreatment, supplied in two nominal permeate capacities: FG-BWRO-824 at 8 m³/h and FG-BWRO-826 at 12.9 m³/h.
What is the difference between permeate flow and feedwater flow?
Permeate (product-water) flow is the treated water the system produces; feedwater flow is the larger volume of raw water drawn in, since part is rejected as concentrate. The 8 m³/h and 12.9 m³/h figures are nominal permeate flows, not feedwater flows.
What feedwater conditions are required?
Standard feedwater should meet SDI <3, turbidity <1 NTU, temperature 5–40 °C, pH 3–11, iron <0.05 mg/L and 0 ppm free chlorine, within a standard TDS application window of ≤2,000 mg/L. Pretreatment is added where these limits are exceeded.
What industries use the system?
Boiler-feedwater and cooling-tower water treatment, food and beverage, textile, paper, chemical and light-industrial process water, and water treatment for mining camps, industrial parks and EPC subcontracts.
What is standard and what requires project confirmation?
The skid-mounted RO unit, cartridge filtration, instrumented gauge panel and PLC control are standard. Pre-treatment type, post-treatment, capacity, materials, voltage and documentation scope are confirmed from feedwater analysis and project requirements.
Is the system suitable for boiler feedwater pretreatment?
Yes, as a pretreatment stage. Whether RO permeate alone meets a specific boiler specification depends on boiler pressure, water chemistry and required post-treatment; the system selection and design notes describe typical additional treatment.
What information is required for final system selection?
Feedwater source and analysis (TDS, hardness, SDI), required permeate capacity and quality, target application, site voltage and frequency, and the desired automation and post-treatment scope.
Contact FG Water
Contact FG Water for feedwater analysis, system sizing, technical configuration, and a project quotation.
Send Your Water Treatment Requirement
Tell us the feedwater, required capacity, target water quality and project conditions. Your inquiry email will automatically include the page you are viewing so our team can understand the exact product, technology or reference that led to your request.
- Feedwater source / available analysis
- Design flow or required production capacity
- Target product-water quality or process duty
- Project country, operating conditions and delivery target